SIM5300E AT Command Manual V1.02
130
0 QOS mean throughput class subscribed value
1..18 QOS mean throughput class
31 QOS mean throughput class best effort
Reference
6.2.5 AT+CGACT PDP Context Activate or Deactivate
AT+CGACT PDP Context Activate or Deactivate
Test Command
AT+CGACT=?
Response
+CGACT: (list of supported <state>s)
OK
Read Command
AT+CGACT?
Response
+CGACT: <cid>,<state>[<CR><LF>+CGACT:<cid>,<state>…]
OK
Write Command
AT+CGACT=<state> [,<cid>]
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
<state> Indicates the state of PDP context activation
0 Deactivated
1 Activated
Other values are reserved and will result in an ERROR response to the Write
Command.
<cid>
A numeric parameter which specifies a particular PDP context
definition (see +CGDCONT Command). If the <cid> is omitted, it only affects
the first cid.
Reference
Note:
This command is used to test PDPs with network simulators. Successful
activation of PDP on real network is not guaranteed.
Refer to AT+CGDATA clarification for more information.