Parameters <currency>
String type (string should be included in quotation marks);
three-character currency code (e.g. "GBP", "DEM");
character set as specified by Command Select TE Character Set +CSCS
<ppu> String type (string should be included in quotation marks); price per
unit; dot is used as a decimal separator(e.g. "2.66")
<passwd> String type (string should be included in quotation marks); SIM
PIN2
Reference
3GPP TS 27.007 [13]
3.2.43 AT+CCWE Call Meter Maximum Event
AT+CCWE Call Meter Maximum Event
Test Command
AT+CCWE=?
Response
+CCWE: (list of supported <mode>s)
OK
If error is related to ME functionality:
+CME ERROR: <err>
Read Command
AT+CCWE?
Response
+CCWE: <mode>
OK
If error is related to ME functionality:
+CME ERROR: <err>
Write Command
AT+CCWE=<mode>
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Unsolicited result codes supported:
+CCWV Shortly before the ACM (Accumulated Call Meter) maximum value is
reached, an unsolicited result code +CCWV will be sent, if enabled by this
command. The warning is issued approximately when 5 seconds call time
remains. It is also issued when starting a call if less than 5 s call time remains.
Parameters <mode>
0 Disable call meter warning event
1 Enable call meter warning event