SIM5300E AT Command Manual V1.02
55
<T2> Max Response Time
r for the multiplexer control channel in units of
ten milliseconds
2-255
Reference
3GPP TS 27.007 [13]
Note:
The multiplexing transmission rate is according to the current serial baud
rate. It is recommended to enable multiplexing protocol under 115200
bit/s baud rate
Multiplexer control channels are listed as follows:
Channel NumberType DLCI
None Multiplexer Control 0
1 3GPP TS 27.007 and 005 1
2 3GPP TS 27.007 and 005 2
3 3GPP TS 27.007 and 005 3
4 3GPP TS 27.007 and 005 4
3.2.35 AT+CNUM Subscriber Number
AT+CNUM Subscriber Number
Test Command
AT+CNUM=?
Response
OK
Execution Command
AT+CNUM
Response
+CNUM: [<alpha1>],<number1>,<type1>[,<speed>,<service>]
[<CR><LF>+CNUM:[<alpha2>],<number2>,<type2>[,<speed>,<service>]
[...]]
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters <alphax> Optional alphanumeric string associated with <numberx>; used
character set should be the one selected with Command Select TE Character
Set +CSCS
<numberx> String type (string should be incl
uded in quotation marks)
phone number of format specified by <typex>
<typex> Type of address octet in integer format (refer GSM04.08[8]
subclause 10.5.4.7)
<speed> As defined by the +CBST Command
<service> (service related to the phone number:)
SIMCOM CONFIDENTIAL FILE