SIM5300E AT Command Manual V1.02
13
Read Command
ATS7?
Response
<n>
OK
Write Command
ATS7=<n>
Response
This parameter setting determines the amount of time to wait for the
connection completion in case of answering or originating a call.
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters <n>
1-255 Number of seconds to wait for connection completion(60 is
the default value)
Reference V.25 te r Note:
I
f called party has specified a high value for ATS0=<n>, call setup may
fail.
The correlation between ATS7 and ATS0 is important.
Example: Call may fail if ATS7=30 and ATS0=20.
ATS7 is only applicable to data call.
2.2.14 ATV TA Response Format
ATV TA Response Format
Execution Command
ATV<value>
Response
This parameter setting determines the contents of the header and trailer
transmitted with result codes and information responses.
When <value>=0
0
When <value>=1
OK
Parameters <value>
0 Information response: <text><CR><LF>
Short result code format: <numeric code><CR>
1 Information response: <CR><LF><text><CR><LF>
Long result code format: <CR><LF><verbose code><CR><LF>
The result codes, their numeric equivalents and brief descriptions of the use
of each are listed in the following table.
ReferenceV.25ter
SIMCOM CONFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM5300E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM5300E and is the answer not in the manual?

SimCom SIM5300E Specifications

General IconGeneral
BrandSimCom
ModelSIM5300E
CategoryControl Unit
LanguageEnglish

Related product manuals