SIM5300E AT Command Manual V1.02
58
AT+CFUN Set Phone Functionality
Test Command
AT+CFUN=?
Response
+CFUN: (list of supported <fun>s),(list of supported <rst>s)
OK
If error is related to ME functionality:
+CME ERROR: <err>
Read Command
AT+CFUN?
Response
+CFUN: <fun>
OK
If error is related to ME functionality:
+CME ERROR: <err>
Write Command
AT+CFUN=<fun>[,<rst>]
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters <fun>
0 Minimum functionality
1 Full functionality (Default)
4 Disable phone both transmit and receive RF circuits.
<rst>
0
Do not reset MT before resetting it to <fun> power level.
(default)
1 Reset the MT before setting it to <fun> power level.
Reference
3GPP TS 27.007 [13]
Note:
Minimum functionality mode (AT+CFUN=0)and RF disabled functionality
mode (AT+CFUN=4) cannot be switched to each other.The <fun> power
level will be written to flash except minimum functionality.AT+CFUN=1,1
can be used to reset module purposely at minimum/full functionality
mode. Response string "OK" will be returned after module resets if baud
rate is set to fixed baud rate.