SIM5300E AT Command Manual V1.02
45
Test Command
AT+CPAS=?
Response
+CPAS: (list of supported <pas>s)
OK
Execution Command
AT+CPAS
Response
TA returns the activity status of ME.
+CPAS: <pas>
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters <pas>
0 Ready (MT allows commands from TA/TE)
1 Unavailable(MT does not allow commands from TA/TE)
2 Unknown (MT is not guaranteed to respond to instructions)
3 Ringing (MT is ready for commands from TA/TE, but the ringer
is active)
4 Call in progress (MT is ready for commands from TA/TE, but a
call is in progress)
5 Asleep(MT is
unable to process commands from TA/TE
because it is in a low functionality state)
Reference
3GPP TS 27.007 [13]
3.2.24 AT+CPIN Enter PIN
AT+CPIN Enter PIN
Test Command
AT+CPIN=?
Response
OK
Read Command
AT+CPIN?
Response
TA returns an alphanumeric string indicating whether some password is
required or not.
+CPIN: <code>
OK
Write Command
AT+CPIN=<pin>[,<new pin>]
Response
TA stores a password which is necessary before it can be operated (SIM PIN,
SIM PUK, PH-SIM PIN, etc.).
If the PIN required is SIM PUK or SIM PUK2, the second pin is required. This
second pin, <new pin>, is used to replace the old pin in the SIM.
OK
SIMCOM CONFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM5300E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM5300E and is the answer not in the manual?

SimCom SIM5300E Specifications

General IconGeneral
BrandSimCom
ModelSIM5300E
CategoryControl Unit
LanguageEnglish

Related product manuals