EasyManua.ls Logo

SimCom SIM5300E

SimCom SIM5300E
267 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SIM5300E AT Command Manual V1.02
45
Test Command
AT+CPAS=?
Response
+CPAS: (list of supported <pas>s)
OK
Execution Command
AT+CPAS
Response
TA returns the activity status of ME.
+CPAS: <pas>
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters <pas>
0 Ready (MT allows commands from TA/TE)
1 Unavailable(MT does not allow commands from TA/TE)
2 Unknown (MT is not guaranteed to respond to instructions)
3 Ringing (MT is ready for commands from TA/TE, but the ringer
is active)
4 Call in progress (MT is ready for commands from TA/TE, but a
call is in progress)
5 Asleep(MT is
unable to process commands from TA/TE
because it is in a low functionality state)
Reference
3GPP TS 27.007 [13]
3.2.24 AT+CPIN Enter PIN
AT+CPIN Enter PIN
Test Command
AT+CPIN=?
Response
OK
Read Command
AT+CPIN?
Response
TA returns an alphanumeric string indicating whether some password is
required or not.
+CPIN: <code>
OK
Write Command
AT+CPIN=<pin>[,<new pin>]
Response
TA stores a password which is necessary before it can be operated (SIM PIN,
SIM PUK, PH-SIM PIN, etc.).
If the PIN required is SIM PUK or SIM PUK2, the second pin is required. This
second pin, <new pin>, is used to replace the old pin in the SIM.
OK
SIMCOM CONFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM5300E

Related product manuals