EasyManuals Logo

SimCom SIM5300E User Manual

SimCom SIM5300E
267 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #73 background imageLoading...
Page #73 background image
SIM5300E AT Command Manual V1.02
62
Reference
3GPP TS 27.007 [13]
3GPP TS 27.007 specifies 30 seconds, so SIMCom deviates from the
specification.
3.2.44 AT+CBC Battery Charge
AT+CBC Battery Charge
Test Command
AT+CBC=?
Response
+CBC: (list of supported <bcs>s),(list of supported <bcl>s),(<voltage>)
OK
Execution Command
AT+CBC
Response
+CBC: <bcs>, <bcl>,<voltage>
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters <bcs> Charge status
0 ME is not charging
1 ME is charging
2 Charging has finished
<bcl> Battery connection level
1...100 battery has 1-100 percent of capacity remaining vent
<voltage>Battery voltage(mV)
Reference
3GPP TS 27.007 [13]
Note:
This command depends on hardware and only be used when battery is
charging.
3.2.45 AT+CUSD Unstructured Supplementary Service Data
AT+CUSD Unstructured Supplementary Service Data
Test Command
AT+CUSD=?
Response
+CUSD: (list of supported <n>s)
OK
Read Command
AT+CUSD?
Response
+CUSD: <n>
OK
Write Command Response
SIMCOM CONFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM5300E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM5300E and is the answer not in the manual?

SimCom SIM5300E Specifications

General IconGeneral
BrandSimCom
ModelSIM5300E
CategoryControl Unit
LanguageEnglish

Related product manuals