SIM5300E AT Command Manual V1.02
9
If connection successful and non-voice call.
CONNECT<tex
t> TA switches to data modeWhen TA returns to Command
mode after call release
OK
If successfully connected and voice call
Reference
V.2 5ter
Note:
This Command may be aborted generally by receiving an ATH
Command or a character during execution. The abort
ing is not
possible during some states of connection establishment such as
handshaking.
<text> output only if ATX<value> parameter setting with the
<value> >0
2.2.5 ATE Set Command Echo Mode
ATE Set Command Echo Mode
Execution Command
ATE<value>
Response
Th
is setting determines whether or not the TA echoes characters received
from TE during Command state.
OK
Parameter <value>
0 Echo mode off
1 Echo mode on
Reference V.25 te r
2.2.6 ATH Disconnect Existing Connection
ATH Disconnect Existing Connection
Execution Command
ATH
Response
Disconnect existing call by local TE from Command line and terminate call
OK
Reference V.25 te r
Note: OK is issued after circuit 109(DCD) is turned off, if it was previously
on.
2.2.7 ATI Display Product Identification Information