SIM5300E AT Command Manual V1.02
“PROIP” bytes.
“PROPORT” Default value is "SIMCOM_MODULE".
“REDIR” This flag controls the redirection mechanism of the SIM800 when
it is acting as HTTP client (numeric). If the server sends a redirect
code (range 30x), the client will automatically send a new HTTP
request when the flag is set to (1). Default value is 0 (no
redirection).
“BREAK” Parameter for HTTP method "GET", used for resum
tra nsfe r.
“BREAKEND”
Parameter for HTTP method "GET", used for resuming broken
transfer. which is used together with "BREAK",
If the value of "BREAKEND" is bigger than "BREAK", the transfer
scope is from "BREAK" to "BREAKEND".
If the value
of "BREAKEND" is smaller than "BREAK", the transfer
scope is from "BREAK" to the end of the file.
“TIMEOUT”
If both "BREAKEND" and "BREAK" are 0, the resume broken
transfer function is disabled.
HTTP session timeout value, scope: 30-1000 second.
Default value is 120 seconds.
HTTP Parameter value. Type and supported content depend on
related <HTTPParamTag>.
“CONTENT” Used to set the “Content-Type” field in HTTP header.
“USERDATA” User data
<HTTPParamValue> HTTP Parameter value. Type and supported content
depend on related <HTTPParamTag>.
<UserdataDelimiter>
The delimiter in the string of “USERDATA” will be
replaced by 0x0D0x0A, limited to 2 characters in length.
Reference
Note:
Not all the HTTP Server supports "BREAK" and "BREAKEND" parameters
10.2.4 AT+HTTPDATA Input HTTP Data
AT+HTTPDATA Input HTTP Data
Test Command
AT+HTTPDATA=?
Response
+HTTPDATA: (list of supported <size>s),(list of supported <time>s)
OK