SIM5300E AT Command Manual V1.02
50
to register to
3 Registration denied
4 Unknown
5 Registered, roaming
<lac> String type (string should be included in quotation marks); two byte
location area code in hexadecimal format
<ci> String type (string should be included in quotation marks); two byte
cell ID in hexadecimal format
Reference
3GPP TS 27.007 [13]
3.2.29 AT+CRLP Select Radio Link Protocol Parameters
AT+CRLP Select Radio Link Protocol Parameters
Test Command
AT+CRLP=?
Response
TA returns values supported.RLP versions 0 and 1 share the same parameter
set.
+CRLP: (list of supported <iws>s),(list of supported <mws>s),(list of
supported <T1>s),(list of supported <N2>s)
OK
Read Command
AT+CRLP?
Response
TA returns current settings for RLP version.RLP versions 0 and 1 share the
same parameter set.
+CRLP: <iws>,<mws>,<T1>,<N2>
OK
Write Command
AT+CRLP=[<iws>[,<mws>[,<T1
>[,<N2>]]]]
Response
TA sets radio link protocol (RLP) parameters used when non-transparent data
calls are setup.
OK
Parameters <iws>
0-61 Interworking window size (IWF to MS)
<mws>
0-61 Mobile window size(MS to IWF)
<T1>
39-255 Acknowledgment timer T1 in 10 ms units
SIMCOM CONFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM5300E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM5300E and is the answer not in the manual?

SimCom SIM5300E Specifications

General IconGeneral
BrandSimCom
ModelSIM5300E
CategoryControl Unit
LanguageEnglish

Related product manuals