SIM5300E AT Command Manual V1.02
167
Test Command
AT+CIPCCFG=?
Response
+CIPCCFG:
(NmRetry:3-8),(WaitTm:2-10),(SendSz:1-1460),(esc:0,1),(Rxmode:0,1),(RxSiz
e:50-1460),(Rxtimer:20-1000)
OK
Read Command
AT+CIPCCFG?
Response
+CIPCCFG:
<NmRetry>,<WaitTm>,<SendSz>,<esc>,<Rxmode>,<RxSize>,<Rxtimer>
OK
Write Command
AT+CIPCCFG=<NmRetry>,<WaitT
m>,<SendSz>,<esc>[,<Rxmode>,
<RxSize>,<Rxtimer>]
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters <NmRetry> Number of retries to be made for an IP packet.
<WaitTm>
Number of 100ms intervals to wait for serial input before
sending the packet.
<SendSz>
Size in bytes of data block to be received from serial port before
sending.
<esc> Whether turn on the escape sequence, default is TRUE.
0 Turn off the escape sequence
1 Turn on the escape sequence
<Rxmode>
Whether to set time interval during output data from serial
port.
0 output data to serial port without interval
1 output data to serial port within <Rxtimer> interval.
<RxSize> Output data length for each time, default value is 1460.
<Rxtimer>
Time interval (ms) to wait for serial port to output data again.
Default value: 50ms
Reference
Note:
This command will be effective only in single connectio
n mode
(+CIPMUX=0)