SIM5300E AT Command Manual V1.02
39
If error is related to ME functionality:
+CME ERROR: <err>
Write Command
AT+CLIP=<n>
Response
TA enables or disables the presentation of the CLI at the TE. It has no effect
on the execution of the supplementary service CLIP in the network.
OK
If error is related to ME functionality:
+CME ERROR: <err>
Unsolicited Result Code
When the presentation of the CLI at the TE is enabled (and calling subscriber
allows), an unsolicited result code is returned after every RING (or +CRING:
<tyn pe>) at a mobile terminating call.
+CLIP: <number>,<type>[,<subaddr>,<satype>,<alphaId>,<CLI validity>]
Parameters <number> String type (string should be included in quotation marks) phone
number of calling address in format specified by <type>
<type> Type of address octet in integer format;
129 Unknown type
161 National number type
145 International number type
177 Network specific number
<subaddr> String type (subaddress of format specified by <satype>)
<satype> Integer type (type of subaddress)
<alphaId> String type (
string should be included in quotation marks)
alphanumeric representation of <number> corresponding to the entry found
in phone book.
<CLI validity>
0 CLI valid
1 CLI has been withheld by the originator.
2 CLI is not available due to interworking problems or limitations
of originating network.
<n>
0 Disable +CLIP notification.
1 Enable +CLIP notification.
<m>
SIMCOM CONFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM5300E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM5300E and is the answer not in the manual?

SimCom SIM5300E Specifications

General IconGeneral
BrandSimCom
ModelSIM5300E
CategoryControl Unit
LanguageEnglish

Related product manuals