144
394149/C
Procedure
1Referringtothewiringdiagramandensuringthatthereis5to10cmslackcableinside
thecabinet,prepareandconnectthecablecorestotheappropriateterminalsand/or
plugswithinorontothecabinet.
2Securethecableusingcableclips.
3Checktheterminalconnectionsagainstthewiringdiagramtoensuretheyarecorrect.
Followthesameprocedureforallthecablesandcableglands.
4Checkthecabinettoensurealltoolsandrubbishareremoved,thenclosethecabinet
door.
5Taketheappropriatesafetymeasures,thenreplacethefusesandapplypowertothe
system.
6Performarelevantsystemtesttoensuretheinstallationhasbeenmadesuccessfully.
Usingmulti-diametercablesealing
Cablesealingsystemsareavailablefromseveralmanufacturers,andmulti-diametertypes
arebecomingincreasinglypopularduetotheireaseofuse.
Prerequisites
Sealingsystemexample;the
nishedassembly
Electricalinstallationscanonlybedonebycertied
electricians.Allnecessarytoolsandinstruments
requiredmustbeavailable.Theinstallationshipyard
mustpreparedetaileddrawingsoftheelectrical
system,andidentifyeachcable.
Context
Onlyabriefdescriptionofthesealingsystemwill
bepresentedhere.Furtherinformationwithrelevant
technicalspecicationsandinstallationdescriptions
mustbeobtainedfromthemanufacturer.
Roxtecmodules(ImagefromRoxtecwebsite)
SimradEK80