System
Day Night Service
Strata CIX Programming Vol.1 12/09 4-25
System
Day Night Service
Program Number(s): 112, 106 and 113
Note Refer to Automatic Day Light Savings Time Change, Program Number “121 Automatic Day Light
Savings Time Change” on page 10-4.
The programs that follow are used to set up Day and Night modes in Strata CIX.
1. Select > System > Day Night Service.
2. Select the Tenant number for which the daily schedules will be configured.
Possible values: 1~8 (default = no value)
3. Enter the Calendar Day (YYYYMMDD) to assign a Working Day Type schedule
… or click on one of the following buttons:
• List – View a summary list of programmed Calendar days.
• Copy Tenant – Copies the currently viewed record to another record(s).
• Get Default - Restores factory default data.
4. Enter remaining Program 112 data.
5. Enter Program 106 data.
6. Enter Program 113 data.
7. Click Submit.
112 Day/Night Mode Calendar
Prerequisite Program: 106
This program enables you to assign Working Day Types for up to 128 unique Calendar Days. These
settings override the default system schedules in the CIX to enable Day/Night scheduling for unique
circumstances.
F
IELD DESCRIPTION
01 Calendar Day Enter the Calendar Day for which to assign a Working Day Type schedule.
Possible values:YYYY = Year, MM = Month, DD = Day (default = no
value)
02 Working Day Type Select the Working Day Type.
Possible values:Delete, Work Day, Non-Work Day or Holiday, (default= no
value)