EasyManua.ls Logo

Strata CIX 100 - Day Night Service; Day;Night Mode Calendar

Default Icon
508 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System
Day Night Service
Strata CIX Programming Vol.1 12/09 4-25
System
Day Night Service
Program Number(s): 112, 106 and 113
Note Refer to Automatic Day Light Savings Time Change, Program Number “121 Automatic Day Light
Savings Time Change” on page 10-4.
The programs that follow are used to set up Day and Night modes in Strata CIX.
1. Select > System > Day Night Service.
2. Select the Tenant number for which the daily schedules will be configured.
Possible values: 1~8 (default = no value)
3. Enter the Calendar Day (YYYYMMDD) to assign a Working Day Type schedule
… or click on one of the following buttons:
List – View a summary list of programmed Calendar days.
Copy Tenant – Copies the currently viewed record to another record(s).
Get Default - Restores factory default data.
4. Enter remaining Program 112 data.
5. Enter Program 106 data.
6. Enter Program 113 data.
7. Click Submit.
112 Day/Night Mode Calendar
Prerequisite Program: 106
This program enables you to assign Working Day Types for up to 128 unique Calendar Days. These
settings override the default system schedules in the CIX to enable Day/Night scheduling for unique
circumstances.
F
IELD DESCRIPTION
01 Calendar Day Enter the Calendar Day for which to assign a Working Day Type schedule.
Possible values:YYYY = Year, MM = Month, DD = Day (default = no
value)
02 Working Day Type Select the Working Day Type.
Possible values:Delete, Work Day, Non-Work Day or Holiday, (default= no
value)

Table of Contents