Strata CIX Programming Vol.1 12/09 9-47
Services
External Devices
Door Phones
Program Number(s): 507, 576, 573 and 508
This command assigns Door Phone parameters.
1. Select Station > Door Phones.
2. Enter Door Phone Number or click one of the following buttons:
- List – View a summary list of programmed Door Phones.
- Create – Assigns a new Door Phone with default settings.
- Copy – Copies settings from an existing Door Phone.
- Delete – Deletes a Door Phone.
- Get Default - sets all data to factory defaults.
3. Enter remaining Program 507 data.
4. Enter Program 576 data.
5. Enter Program 508 data.
6. Click Submit.
507, 573 Door Phone Assignment
Prerequisite Program: None
This assignment configures Door Phone Control Boxes (DDCBs) and Door Phones (MDFBs). DDCBs can
be connected to ADKU, PDKU and/or BDKU interface PCBs. Up to three MDFBs can be connected to one
DDCB. A door lock control relay may be assigned to the B output of the DDCB in place of a MDFB door
phone (see “508 Door Lock Control Assignment” on page 9-50).
F
IELD DESCRIPTION
00 Door Phone Number Enter the door phone number.
Possible values:1~6 (CIX40, CIX100), 1~9 (CIX200, CIX670/CIX1200
Basic),
1~24 (CIX670/CIX1200 Exp.), (default = no value)
Door phone numbering for the CIX40, CIX100, CIX670 and CIX1200is as
follows:
• DDCB 1 provides door phone numbers 1~3, 2 can be a door phone or
door lock.
• DDCB 2 provides door phone numbers 4~6, 5 can be a door phone or
door lock.