Telephone Button Programming
Telephone Button Overview
Strata CIX Programming Vol.1 12/09 13-3
Telephone Button
Programming
Programming Sub-parameters
Some commands enable programming of Sub-parameters to further refine Strata CIX settings. Internet or
Network IP addresses are entered using sub-parameter data. IP addresses are displayed as four three-
digit values, or Octets, separated by “periods” (e.g., 192.168.255.253). (If your programming telephone’s
LCD is only capable of displaying the IP information three digits, or one Octet, at a time, selecting FB01 in
Program 916 displays the first Octet, 192, on the LCD. To view or change the next Octet (in this example
168) in the IP Address, press the Speaker button. Pressing Speaker again, displays the following Octet (in
this example 255)).
The following is an example from Program 200, FB04. FB04 is broken down into three sub-parameters as
follows COS DAY1, COS DAY2 and COS NIGHT.
1. At the SELECT PARAM prompt, press FB04.
2. At the COS DAY1= prompt, enter a value from 1~32.
3. Press Speaker.
4. At the COS DAY2= prompt, enter a value from 1~32.
5. Press Speaker.
6. At the COS NIGHT= prompt, enter a value from 1~32.
7. Press Hold to submit.
8. Press another FBnn button to program more parameters
… or press Hold again to program a new DN.
Note To change one of the sub-parameters, you must proceed through all three sub-parameters before
pressing Hold. For example, to change the value of COS DAY1, you must change the COS DAY1
value, then press Speaker twice, and finally, press Hold.
Button Programming Procedure
Step 1: Enter Program Mode
Enter the button sequence displayed below to enter the CIX1200/CIX670 programming interface from a
station.
1. Log in by pressing: Hold *#*#1*2*3*.
2. At the PASSWORD= prompt, enter your password. Default is 0000.
3. Press
Hold.
Step 2: Enter Program Number
1. At the PROG= prompt enter the three digit program code (e.g., 200) and press Hold.
2. Programmable parameters are identified by the FB LEDs that are illuminated on the DKT. Go to
“Choose a Button Sequence” on page 13-4 Press on the related FBnn button to program a parameter
or if there are no illuminated FB LEDs, continue to Step 3.
Step 3: Enter FB00 Parameters
FB00 parameters designate a specific station, trunk, or circuit to be programmed. The FB00 prompt (e.g.,
EQUIP=, DN=, INDEX=, etc.) appears automatically in the LCD screen.
1. At the FB00 prompt, enter the desired value using the telephone number pad.
2. Press Hold.