EasyManua.ls Logo

Strata CIX 100 - Table of Contents

Default Icon
508 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Station
Assignment
5-8 Strata CIX Programming Vol.1 12/09
49 IP Phone Login Password Whether or not to apply the Login Password Authentication - Uses the
Personal Password (43)
Possible values:Enabled or Disabled (Default)
50 Transfer Registration Whether or not to apply Transfer Registration - Set to Enable to allow IP
Mobility for this DN.
Possible values:Enabled or Disabled (Default)
Note Assign a “Phone Logout” feature key on this DN.
51 Station Connecting
Equipment
Enter the PDN equipment number (0000 means auto assignment).
IPT1020-SD must be installed on BIPU-M; IPT1020 cannot be installed on
LIPU/LIPS, MIPU or GIPx.
SIP phones must be installed on LIPU/LIPS, MIPU or GIPx; SIP phones
cannot be installed on BIPU-M
IPT2000 series and IP Softphones can be installed on LIPU/LIPS, MIPU,
GIPx or BIPU-M (see Prog 260 for LIPU/LIPS, MIPU or GIPx PDN
assignments). MIPU and GIPU require R5.0 software or higher.
Cabinet numbers:
CIX100: Base, Exp.01
CIX200: Base 01, Exp.02
CIX670: Base 01, Exp 02~07.
CIX1200: Base 01, Exp 02~12
Slot numbers:
CIX100: Base 01, Exp.05~08
CIX100: ACTU Relay Equipment= Cab 02, Slot 05.
CIX100: ASTU Equipment=010901 and 010902
CIX200: Base/Exp.01~04
CIX200: LSLU Equipment=010401 and 010402.
CIX670/1200: Base 01~08
CIX670/1200: Exp.01~10
CTX28 and CIX40 assignments below are hard coded and cannot be
changed.
01, 05 – GVMU - 28, GVPH - 40 R1HW, GIPx, MIPU or GCOCIH - 40 R2HW
01, 06 – GIPx, MIPU16 or GCOCIH - 40 R1HW, no card - 28, 40 R2HW
52 Simple System SpeedDial Whether or not to system speed dial supplement is allowed.
Possible values:Enabled or Disabled (Default)
53 Analog Station
Disconnect Signal
Whether or not Analog Station Disconnect Signal is sent. Refer to 208 Timer”
on page 5-25.
Possible values:Enabled or Disabled (Default)
Table 5-1 Station Assignment Data for IP, and SIP Telephones (Prog 260) (continued)

Table of Contents