Station
Assignment
Strata CIX Programming Vol.1 12/09 5-25
Station
208 Timer
Program Number(s): 208
Prerequisite Program:
200 page 5-1
Assigns timing parameters to Primary DNs.
1. Select: Station > Station Assignments.
2. Click on the Timer tab.
3. Enter a DN in the Primary DN field or select an existing record by clicking one of the following buttons:
List – select from the list of programmed DKTs on the right side of the screen.
Copy – Enter a DN in the Primary DN field and click Copy. Enter a new DN to assign existing
Station Timer settings.
4. Select the desired values. See descriptions below.
5. Get Default will set all data to the factory defaults.
6. Click Submit
F
IELD DESCRIPTION
Prime DN Enter the Prime DN.
Possible values:Up to 5 digits (default = no value)
01 Automatic Busy Redial
Retry Count
Enter the number of retry attempts made by ABR when dialing a busy
telephone number.
Possible values:5~20 (default = 15)
02 Automatic Busy Redial
Retry Interval Timer
Select the amount of time (in seconds) ABR waits between dialing attempts.
Possible values:30~180 (default = 60)
03 Automatic Busy Redial
Recall Timer
Select the number of seconds ABR will call back the station after receiving ring
back tone from the dialed number.
Possible values:5~60 (default = 20)
04 Hold Recall Timer Select the number of seconds before a held call recalls.
Possible values:0~255 (default = 60)
05 First Interdigit Timer Enter the First Interdigit Timer in seconds.
Possible values:1~180 (default = 15)
06 Second Interdigit Timer Enter the Second Interdigit Timer in seconds.
Possible values:1~180 (default = 5)
07 Ring Xfer No Answer
Timer
Enter the Ring Xfer No Answer Timer in seconds.
Possible values:1~600 (default = 32)
08 SLT MW Lamp Signal
Timer
The time in seconds to wait before sending the Message Waiting Lamp signal
to a standard telephone.
Note Some SLTs do not support MW lamps
Possible values:1(Default) - 10; 0 = MW signal not sent
09 Analog Station
Disconnect Signal Timer
The time in seconds, after the the disconnect until the disconnect signal is sent.
Possible values:1~120 (default = 1)