Station
Assignment
5-24 Strata CIX Programming Vol.1 12/09
Door Lock Sub-parameters
GCO
1. Select GCO No.
Possible values:1~20 (CIX200, CIX670 Basic, CIX1200 Basic), 1~32 (CIX100),
1~128 (CIX670 Exp, CIX1200 Exp A), 1~220 (CIX1200 Exp B),
(default = no value)
2. Select Index.
Possible values:1~128 (CIX200, CIX670), 1~32 (CIX100), 1~220 (CIX1200)
(default = no value)
3. Enter Owner DN.
Possible values:Any string up to 5 digits
4. Select Ringing Assignment for Day1, Day2 and Night.
Possible values:No Ring, Immediate Ring, Delayed Ring1 and Delayed Ring2.
5. Select Tone Pitch. 1~4 (default = 1)
Pooled Line Key
1. Select Pool Line No.
Possible values:1~32 (CIX100), 1~50 (CIX200, 670 Basic, 1200 Basic), 1~‘28
(CIX670 Exp, 1200 Exp A) 1~220 (CIX1200 Exp B)
(default = no value)
2. Select Ringing Assignment for Day1, Day2 and Night.
Possible values:No Ring, Immediate Ring, Delayed Ring1 and Delayed Ring2.
3. Select Tone Pitch. 1~4 (default = 1)
F
IELD DESCRIPTION
Door Unlock Select Door Lock No.
Possible values:1~10 (default = 1)
F
IELD DESCRIPTION