Program 921 Control Setup
Prerequisite Program: None
Traffic Measurement (TM), when ON, sends data each hour. The data is stored in the SD/SM card on the
processor in a TRAFFIC folder or it can be sent to an external device via LAN or RS-232. Each file is
named: MMDDHHNN.trf.
MM = Month (01 - 12)
DD = Day (01 - 31)
HH = Hour (01 - 24)
NN = Sequence Number
1. Select Alarm/Traffic > Traffic Measure > Control Setup
2. Enter data.
3. Click Submit.
F
IELD DESCRIPTION
01 Traffic Measurement On/
Off
Select Enable to run Traffic Measurement. Select Disable to stop
Traffic Measurement.
02 Send TM Data to SM/SD
Card
Enable To send data to the SM/SD card (TRAFFIC
folder) and, if setup in I/O Device configuration,
to an external device (RS232c or LAN).
Disable To send data only to the external device. The
external device must be set (refer to the I/O
Device configuration Program 803).
03 Select Tenant to Measure Select the System Day/Night Table to be used for the work day and
non-work day and holiday definitions. This does not select TM by
tenant.
04 ~ 12 Time Zones Set the time zone (report hours) in each category.
13 Traffic Measurement
Units
Traffic intensity units
Possible values: Erlang or CCS (default)
ILG tab - 14 Select ILG Select which Incoming Line Group should have traffic measurment
enabled/disabled
OLG tab - 15 Select OLG Select which Outgoing Line Group should have traffic measurment
enabled/disabled
DID-Numbers
16 Select DID ILG
Select DID Number
Select which Incoming DID Line Group should have traffic
measurement enbled/disabled for selected DID numbers
The DID number in the selected DID Incoming Line Group that should
have traffic measurement enabled/disabled. Use “?” to assign wild
cards.