Station
Assignment
5-26 Strata CIX Programming Vol.1 12/09
216 Emergency Ringdown Assignment
Program Number(s): 216
Prerequisite Program:
200 page 5-1
Assigns Emergency Ring Down parameters to Primary DNs.
1. Select > Station > Station Assignments.
2. Click on the RingDown tab.
3. Enter a DN number in the Primary DN field or select an existing record by clicking one of the following
buttons:
• List – select from the list on the right side of the screen.
• Copy – Enter a DN in the Primary DN field and click Copy. Enter a new DN to assign existing
Station Timer settings.
4. Select the desired values. See descriptions below.
5. Get Default will set all data to the factory defaults
6. Click Submit
F
IELD DESCRIPTION
01 Emergency
Ringdown
Enable an Emergency Ringdown Number.
Possible values:Enable or Disable (default = Disable)
02 Emergency
Ringdown Timer
Enter the length of off-hook time that will cause a DN to originate an Emergency.
Possible values:0~60 (default = 0)
Note For DKT, IP, and IPT stations, do not set the time to more than 30 seconds.
03 Emergency
Ringdown
Destination
Enter the destination DN for the Emergency Ringdown.
Possible values:Up to 5 digits (default = no value)