Trunks
Strata CIX Programming Vol.1 12/09 6-19
Trunks
318 DID Intercept Assignments
Prerequisite Program: 304 page 6-2
This command assigns the DID Routing table when DID numbers are undefined or not received.
1. Select > Trunk > DID Intercept.
2. Enter an ILG Number or choose from the list of programmed ILGs on the right side of the screen.
3. Enter DID Type in the 01 Type field.
4. Enter DID Intercept Assignment data.
5. Get Default - restores data to factory defaults.
6. Click Submit.
F
IELD DESCRIPTION
ILG Number Enter ILG number.
Possible values:1~6 CTX28, 1~32 CIX40, 1~32 CTX/CIX/100, 1~50 CIX200,
1~50 CTX/CIX 670 BCTU only or BBCU only, 1~128 CTX/
CIX670 BCTU + BEXU or BBCU + BECU, 1~50 CIX1200 HCTU
only, 1~128 CIX1200 HCTU + HEXAU, 1~220 CIX1200 HCTU +
HEXBU
(default = 0)
01 Type No DID - set destination that should ring when the received DID number does not
match DID numbers in this group's DID table.
Not Determined - set the destination that should ring when the normal
programmed ringing destination is disconnected.
Possible values:No DID (default) or Not Determined
02 MOH Source Select Music On Hold.
Possible values:Quiet Tone, External 1~15, or Internal (default)
03 Group CO Destination GCO Key Group number.
Possible values:0~32 (CIX100), 0~50 (CIX200, CIX670/CIX1200 Basic),
0~128 (CIX670 Exp, CIX1200 Exp A), 0~220 (CIX1200 Exp B)
(default = 0)
04 Pooled Line Group POOL Line Key Group Number.
Possible values:0~32 (CIX100), 0~50 (CIX200, CIX670/CIX1200 Basic),
0~128 (CIX670 Exp, CIX1200 Exp A), 0~220 (CIX1200 Exp B)
(default = 0)