Station
Assignment
Strata CIX Programming Vol.1 12/09 5-11
Station
03 Keystrip Button
Quantity
Select the number of feature buttons to assign to this station.
Note Although the scroll down menu enables you to choose any value
from 1~24, valid values are 10, 14, and 20.
Possible values:1, 3, 7, 8, 10, 14, or 20 (default)
Applies 1, 3, 10, 14, or 20 button keystrip type to digital telephones:
1 and 3 button keystrips apply to DKT2001, DKT3001/3201|, and DP5008
7 button keystrips apply to DKT3007/32307 and SoftIPT
8 button keystrips apply to IPT2008-SDL
10 button keystrips apply to DKT2010, DKT3001/3201, DP5018, DP5022,
DP5122, DP5130, IP5122-SD -SDC and IP5131-SDL.
Note To set as or change from DP5130 or IP5131-SDL, refer to Keystrip
Type.
14 button keystrips apply to the Large LCD DKT3014/3210
20 button keystrips apply to DKT2020, DKT3020/3220, DP5032, DP5132
and IP5132-SD
04 Add-on Modules Select the number of DADM or LM Add-on-Modules assigned to this
station.
If the Add-on-Module is an LCD Line Module, LM5110, identify it as such in
parameter 40 and/or 41 of this program.
Possible values:None (default), 1 unit, or 2 units
05 Tone Ring/Voice
Announce
Set PDN to have Tone First or Voice First signaling when called.
For each iES32 PDN, set to “Tone First”; if set to Voice First iES32 will not
answer.
Possible values:Tone or Voice (default)
06 OCA Type Select the OCA type. This field must be programmed with Auto OCA
Originate below.
Possible values:Handset (default) or Speaker
09 Handsfree MIC
Setting
If you call a station configured for Voice First signaling you can use this
parameter to enable the called parties microphone from your DKT.
Possible values:Enable or Disable (default = Enable)
10 Handsfree Tone If you call a DKT configured for Voice First signaling you can use this
parameter to send a splash tone to the called party.
Possible values:Enable or Disable (default = Enable)
11 Ext. Ring Repeat Enable repetitive ringing for incoming CO / PBX / Centrex signals.
Disabling this parameter defaults to standard CO ringing pattern (1 sec on /
3 sec Off).
Possible values:Enable or Disable (default = Disable)