Trunks
ISDN
6-36 Strata CIX Programming Vol.1 12/09
03 Facility Code Enter the supplied Facility code value from the PSTN. If no data is entered in this
field any previously entered data is deleted.
Possible values:00~31(default = no value)
04 Service Parameters Enter the service parameters supplied from PSTN. If no data is entered in this field
any previously entered data is deleted.
Possible values:Up to 5 digits (default = no value)
05 Network ID Enter the Network ID code supplied from PSTN (this field is required if you selected
Inter LATA Out WATS type of service). If no data is entered in this field any
previously entered data is deleted.
Possible values:3 to 4 digits (default = no value)
06 Incoming Line
Group
Specify the ILG for this facility.
Possible values:1~32 CTX/CIX/100, 1~50 CIX200, 1~50 CTX/CIX 670 BCTU only
or BBCU only, 1~50 CIX200, 1~128 CTX/CIX670 BCTU + BEXU or
BBCU + BECU, 1~50 CIX1200 HCTU only, 1~128 CIX1200 HCTU
+ HEXAU, 1~220 CIX1200 HCTU + HEXBU
(default = 0)
07 Outgoing Line
Group
Specify the OLG for this facility.
Possible values:1~32 CTX/CIX/100, 1~50 CIX200, 1~50 CTX/CIX 670 BCTU only
or BBCU only, 1~50 CIX200, 1~128 CTX/CIX670 BCTU + BEXU or
BBCU + BECU, 1~50 CIX1200 HCTU only, 1~128 CIX1200 HCTU
+ HEXAU, 1~220 CIX1200 HCTU + HEXBU
(default = 0)
08 Min Calls Zone 1 Select the minimum number of Bch in Time Zone 1.
Possible values:0~47 (default = 0)
09 Max Calls Zone 1 Select the maximum number of Bch in Time Zone 1.
Possible values:0~47 (default = 47)
10 Min Calls Zone 2 Select the minimum number of Bch in Time Zone 2.
Possible values:0~47 (default = 0)
11 Max Calls Zone 2 Select the maximum number of Bch in Time Zone 2.
Possible values:0~47 (default = 47)
12 Min Calls Zone 3 Select the minimum number of Bch in Time Zone 3.
Possible values:0~47 (default = 0)
13 Max Calls Zone 3 Select the maximum number of Bch in Time Zone 3.
Possible values:0~47 (default = 47)
F
IELD DESCRIPTION