Operation
System Setup
Strata CIX Programming Vol.1 12/09 10-7
Operation
From the Local Folder drop down, select the Network eManager PC SM/SD folder and file(s) that
should be copied to the CIX SM/SD card.
From the CIX SM/SD Folder drop down, select the CIX SM/SD folder to which the files should be
copied to - then click on Upload.
Delete SM File: Delete files stored on the CIX SM/SD card.
From the CIX SM/SD drop down, select the CIX SM/SD folder and file(s) that should be deleted -
them click Delete SM file.
CIX SM/SD Folders
Running the Normal and Forced options of this program creates five folders on the SM/SD card as follows:
Admlog – The Admlog folder saves a history of CIX Administration (programming) command entries in
xxx.SNP and xxx.DKT files. SNP files provide a log of Network eManager entries and DKT files provide
a log of programming telephone entries.
Errlog – System error logs are saved into this folder. See Maintenance chapter, Event Trace Control
Programs 903, 904 and 905 to set up trace.
Evnttrce – Network eManager Event Trace files are saved into this folder.
Progdata – Your Strata CIX programmed settings are all saved in this folder. When a backup is
performed, Strata CIX saves programmed data to the Progdata folder as a default.dat file.
Note To perform the backup function you must first delete any existing default.dat files to allow CIX to
create a new default.dat file.
Program – The operating software of the Strata CIX is saved in this folder as a nhs.prg file.
SM/SD Errors
Any error causes the SM/SD LED to flash (0.25sec ON – 0.25sec OFF continuous) except when the SM/
SD Volume Label is UPDATE; in this case the SM/SD LED will always flash.
SM/SD LED Specification
SM/SD LED, located near the SM/SD slot on the CIX processor, is lit when the following occurs:
The SM/SD is accessed for read and write.
Errors are detected. See above for the detail of errors.
The SM/SD is inserted into the slot, SM/SD LED blinks once. This is because the system accesses the
media to read the housekeeping data. When it does not blink, it means that the SM/SD is not detected
by the system at all. If the blink does not stop, it means that any of above error is detected or the SM/
SD volume label is UPDATE.