SVAN 979 User Manual - Appendixes
start date of the measurement
start time of the measurement
measurement mode:
0 – vibration measurement mode,
1 – sound measurement mode,
measurement function
1 – Level Meter
2 – 1/1 Octave
3 – 1/3 Octave
5 – Loudness
6 – FFT
7 – Tonality
8 – RT60
15 – 1/6 Octave
16 – 1/12 Octave
19 - STIPA
measurement Input type:
2 – measurement with the microphone
5 – measurement with the vibration accelerometer
measurement range:
1 – Low
2 – High
for sound measurement mode:
0 – measurement of statistical results with the linear detector
1 – measurement of statistical results with the exponential
detector
number of measurement cycles (zero means infinity) - the parameter
is important if the duration of the measurement cycle (IntTimeSec) is
finite; for infinite measuring cycle time this parameter is irrelevant
(see SplitCycles)
number of measurement profiles
measurement start delay in seconds
duration of one measurement cycle in seconds (zero means infinity)
measurement start synchronization:
0 – no synchronization,
-1 – synchronization to full second
1 – synchronization to full minute
15 – synchronization to full 15 minutes
30 – synchronization to full 30 minutes
60 – synchronization to full hour
detector type for RMS/Leq results:
0 – measurement with linear detector
1 – measurement with exponential detector
bit mask of logged spectra results:
8 – RMS/Leq spectrum (applies to octave spectra)
8 – average spectrum (applies to FFT spectrum)
the remaining masks are reserved