Do you have a question about the Thermo Scientific Applied Biosystems SeqStudio Genetic Analyzer and is the answer not in the manual?
Brand | Thermo Scientific |
---|---|
Model | Applied Biosystems SeqStudio Genetic Analyzer |
Category | Measuring Instruments |
Language | English |
Provides a description of the Applied Biosystems SeqStudio Genetic Analyzer and its capabilities.
Details the front and interior components of the SeqStudio Genetic Analyzer.
Lists available consumables for the SeqStudio Genetic Analyzer, including cartridges and buffer containers.
Describes the functionalities of the SeqStudio software applications like Data Collection and Plate Manager.
Explains the different ways the SeqStudio Genetic Analyzer can connect to a network or computer.
Highlights safety hazards and precautions associated with operating the instrument.
Provides guidelines for sample preparation for fragment and sequence analysis.
Details steps for preparing the instrument, including checking consumables status.
Explains the interaction between the instrument and the Connect cloud-based platform.
Provides instructions on how to connect the instrument to the Connect cloud-based platform account.
Details the roles and functions of administrators for instruments on the Connect platform.
Describes the three main components of the SAE v2.0 module: Console, Server, and Client.
Explains how to sign in to the instrument when the SAE module is enabled.
Details the e-signature requirements that may be enforced before starting a run.
Explains the various settings available for plate setup in the Plate Manager.
Guides users on creating a new plate setup using default settings via the Plate Manager.
Covers advanced plate settings like specifying replicate injections in the Plate Manager.
Describes the PSM and CSV file formats for importing plate setups into the instrument.
Instructions for creating or importing a plate setup directly on the instrument.
Details how to configure optional settings for a plate setup on the instrument.
Steps for loading plates or tubes into the instrument's autosampler.
Guidance on selecting a plate setup and initiating a run on the instrument.
How to view the status and results of a run directly on the instrument's touchscreen.
Instructions for viewing run results and analyzing data on the instrument.
Guidance on using secondary analysis software to analyze exported data.
Steps for exporting data files and quality control reports from the instrument.
Instructions for managing and creating run modules within the Plate Manager software.
Details on managing size standard definitions used for fragment analysis.
Guidance on managing analysis settings for sequencing and fragment analysis.
Steps for connecting the SeqStudio Genetic Analyzer to a network drive.
Instructions for linking the instrument to the Thermo Fisher Connect cloud platform.
Details on managing run modules, read lengths, and run times for the instrument.
Covers routine maintenance procedures for the instrument, including buffer checks.
Information on cartridge storage, handling, and history tracking.
Instructions for installing and assembling the SeqStudio Genetic Analyzer Cathode Buffer Container.
Provides a general workflow for troubleshooting instrument issues.
Explains common data quality alerts and their recommended actions.
Addresses common problems and solutions related to instrument operation.
Covers troubleshooting steps for issues related to samples and data analysis.
Outlines the steps to set up instrument access for the Connect cloud-based platform.
Instructions for linking the instrument to the Connect platform using a mobile device.
Steps to link the instrument to the Connect platform using a unique link code.
Procedures for performing system dye calibration and managing custom dyes.
Instructions for performing install runs to ensure instrument performance.
Details the requirements and components needed for HID analysis.
Provides a step-by-step workflow for performing HID analysis.
Instructions for managing kit files for HID applications in the software.
Information on available run modules, their read lengths, size ranges, and run times.
Lists software, equipment, consumables, and reagents not included with the instrument.
Provides the physical dimensions and weight of the SeqStudio Genetic Analyzer.
Specifies the acceptable environmental conditions for instrument operation.
Details the electrical specifications, including voltage, power, and protective devices.
Outlines safety practices and required safety equipment for laboratory personnel.
Provides essential general safety guidelines for using the instrument and handling chemicals.
Details safety precautions related to instrument operation, electrical hazards, and lasers.
Guidelines for the safe handling, storage, and disposal of chemicals.
Information on safely handling biological samples and preventing infectious disease transmission.
Lists related user guides, bulletins, and other documentation for the SeqStudio system.
Provides contact information and resources for technical support and product inquiries.