4.9 Test Run with Load Connected
u
Test Run with the Load Connected
After performing a no-load test run, connect the motor and proceed to run the motor and load together.
n
Notes on Connected Machinery
Clear the area around the motor.
The motor should come to a complete stop without problems.
Connect the load and machinery to the motor.
Fasten all installation screws properly and check that the motor and connected machinery are held in place.
Confirm that the Fast Stop circuit or mechanical safety measures operate correctly.
Be ready to press the STOP button in case of emergency.
n
Checklist Before Operation
The motor should rotate in the proper direction.
The motor should accelerate and decelerate smoothly.
n
Operating the Motor under Loaded Conditions
Test run the application similarly to the no-load test procedure when connecting the machinery to the motor.
Monitor U1-03 for overcurrent during operation.
If the application permits running the load in the reverse direction, change the motor direction and the frequency reference
while watching for abnormal motor oscillation or vibration.
Correct any problems that occur with hunting, oscillation, and other control-related issues.
4.9 Test Run with Load Connected
114
YASKAWA ELECTRIC SIEP C710616 31B YASKAWA AC Drive – A1000 Technical Manual

Table of Contents