No.
(Addr.
Hex)
Name Description Values Page
L3-22
(4F9)
Deceleration Time at Stall
Prevention during
Acceleration
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
OLV/PM
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
OLV/PM
Sets the deceleration time used for Stall Prevention during acceleration in
OLV/PM.
Default: 0.0 s
Min.: 0.0
Max.: 6000
252
L3-23
(4FD)
Automatic Reduction
Selection for Stall
Prevention during Run
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLVV/f V/f w PG
0: Sets the Stall Prevention level set in L3-04 that is used throughout the entire
frequency range.
1: Automatic Stall Prevention level reduction in the constant output range. The
lower limit value is 40% of L3-06.
Default: 0
Range: 0, 1
253
L3-24
(46E)
Motor Acceleration Time for
Inertia Calculations
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLVV/f V/f w PG OLV
Sets the time needed to accelerate the uncoupled motor at rated torque from
stop to the maximum frequency.
Default:
<5> <6>
<7>
Min: 0.001 s
Max: 10.000 s
255
L3-25
(46F)
Load Inertia Ratio
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLVV/f
OLV/PM AOLV/PM
OLV
Sets the ratio between the motor and machine inertia.
Default: 1.0
Min.: 1.0
Max.: 1000.0
255
L3-26
(455)
Additional DC Bus
Capacitors
All Modes
When DC bus capacitors have been added externally, be sure to add those
values to the internal capacitor table for proper DC bus calculations.
Default: 0 μF
Min: 0
Max: 65000
256
L3-27
(456)
Stall Prevention Detection
Time
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLVV/f
OLV/PM
V/f w PG OLV
Sets the time the current must exceed the Stall Prevention level to activate
Stall Prevention.
Default: 50 ms
Min.: 0
Max.: 5000
256
<1> Upper limit is dependent on parameters C6-01, Drive Duty Selection, and L8-38, Frequency Reduction Selection.
<2> The setting range is 0 to 2 in CLV, OLV/PM, or AOLV/PM, control modes.
<3> Default setting is dependent on parameter E1-01, Input voltage Setting.
<4> Default setting is determined by parameter A1-02, Control Mode Setting.
<5> Parameter value changes automatically if E2-11 is manually changed or changed by Auto-Tuning.
<6> Default setting is dependent on parameters C6-01, Drive Duty Selection, and o2-04, Drive Model Selection.
<7> Default setting is dependent on parameter E5-01, Motor Code Selection.
u
L4: Speed Detection
No.
(Addr.
Hex)
Name Description Values Page
L4-01
(499)
Speed Agreement Detection
Level
All Modes
L4-01 sets the frequency detection level for digital output functions H2-oo
= 2, 3, 4, 5.
Default: 0.0 Hz
Min.: 0.0
Max.: 400.0
256
L4-02
(49A)
Speed Agreement Detection
Width
All Modes
L4-02 sets the hysteresis or allowable margin for speed detection.
Default: 2.0 Hz
<1>
Min.: 0.0
Max.: 20.0
256
L4-03
(49B)
Speed Agreement Detection
Level (+/-)
All Modes
L4-03 sets the frequency detection level for digital output functions H2-oo
= 2, 3, 4, 5.
Default: 0.0 Hz
Min.: -400.0
Max.: 400.0
256
L4-04
(49C)
Speed Agreement Detection
Width (+/-)
All Modes
L4-04 sets the hysteresis or allowable margin for speed detection.
Default: 2.0 Hz
<1>
Min.: 0.0
Max.: 20.0
256
L4-05
(49D)
Frequency Reference Loss
Detection Selection
All Modes
0: Stop. Drive stops when the frequency reference is lost.
1: Run. Drive runs at a reduced speed when the frequency reference is lost.
Default: 0
Range: 0, 1
257
B.10 L: Protection Function
430
YASKAWA ELECTRIC SIEP C710616 31B YASKAWA AC Drive – A1000 Technical Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA AC Drive-A1000 and is the answer not in the manual?

YASKAWA AC Drive-A1000 Specifications

General IconGeneral
BrandYASKAWA
ModelAC Drive-A1000
CategoryController
LanguageEnglish

Related product manuals