E3-01 (Motor 2 Control Mode) Dependent Parameters
Table B.4 E3-01 (Motor 2 Control Mode) Dependent Parameters and Default Values
No. Name Setting Range Resolution
Control Modes (E3-01)
V/f (0) V/f w/PG (1) OLV (2) CLV (3)
E3-04 Motor 2 Maximum Output Frequency 40.0 to 400.0 0.1 Hz
The default settings of these parameters depends on the
control mode and the drive capacity. The values are equal
to the Motor 1 settings. Refer to V/f Pattern Default
Values on page 459.
E3-05 Motor 2 Maximum Voltage 0.0 to 733.1 0.1 V
E3-06 Motor 2 Base Frequency 0.0 to 400.0 0.1 Hz
E3-07 Motor 2 Middle Output Frequency 0.0 to 400.0 0.1 Hz
E3-08 Motor 2 Middle Output Frequency Voltage 0.0 to 733.1 0.1 V
E3-09 Motor 2 Minimum Output Frequency 0.0 to 400.0 0.1 Hz
E3-10 Motor 2 Minimum Output Frequency Voltage 0.0 to 733.1 0.1 V