No.
(Addr.
Hex)
Name Description Values Page
C6-03
(225)
Carrier Frequency Upper
Limit
All Modes
Note: C6-04 and C6-05 are available only in V/f and V/f w/PG control
modes.
Determines the upper and lower limits for the carrier frequency.
In OLV, C6-03 determines the upper limit of the carrier frequency.
Carrier Frequency
E1-04
Max Output
Frequency
Output Frequency
× (C6-05) × K
Output
Frequency
C6-03
C6-04
Default:
<2>
Min.: 1.0 kHz
Max.: 15.0 kHz
167
C6-04
(226)
Carrier Frequency Lower
Limit
Default:
<2>
Min.: 1.0 kHz
Max.: 15.0 kHz
167
C6-05
(227)
Carrier Frequency
Proportional Gain
Default:
<2>
Min.: 0
Max.: 99
167
C6-09
(22B)
Carrier Frequency during
Rotational Auto-Tuning
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLVOLV CLV
0: Carrier Frequency = 5 kHz
1: Setting value for C6-03
Default: 0
Range: 0, 1
168
<1> Default setting value is dependent on the drive model (o2-04), the control mode (A1-02), and the Drive Duty (C6-01).
<2> Default setting value is dependent on parameter C6-02, Carrier Frequency Selection.
B.5 C: Tuning
396
YASKAWA ELECTRIC SIEP C710616 31B YASKAWA AC Drive – A1000 Technical Manual

Table of Contents