No. Name
User
Setting
E3-08 Motor 2 Mid Output Frequency Voltage
E3-09 Motor 2 Minimum Output Frequency
E3-10 Motor 2 Minimum Output Frequency Voltage
E3-11 Motor 2 Mid Output Frequency 2
E3-12 Motor 2 Mid Output Frequency Voltage 2
E3-13 Motor 2 Base Voltage
E4-01 Motor 2 Rated Current
E4-02 Motor 2 Rated Slip
E4-03 Motor 2 Rated No-Load Current
E4-04 Motor 2 Motor Poles
E4-05 Motor 2 Line-to-Line Resistance
E4-06 Motor 2 Leakage Inductance
E4-07 Motor 2 Motor Iron-Core Saturation Coefficient 1
E4-08 Motor 2 Motor Iron-Core Saturation Coefficient 2
E4-09 Motor 2 Mechanical Loss
E4-10 Motor 2 Iron Loss
E4-11 Motor 2 Rated Capacity
E5-01 Motor Code Selection
E5-02 Motor Rated Power
E5-03 Motor Rated Current
E5-04 Number of Motor Poles
E5-05 Motor Stator Resistance
E5-06 Motor d-Axis Inductance
E5-07 Motor q-Axis Inductance
E5-09 Motor Induction Voltage Constant 1
E5-11 Encoder Z-pulse Offset
E5-24 Motor Induction Voltage Constant 2
F1-01 PG 1 Pulses Per Revolution
F1-02 Operation Selection at PG Open Circuit (PGo)
F1-03 Operation Selection at Overspeed (oS)
F1-04 Operation Selection at Deviation
F1-05 PG 1 Rotation Selection
F1-06 PG 1 Division Rate for PG Pulse Monitor
F1-08 Overspeed Detection Level
F1-09 Overspeed Detection Delay Time
F1-10 Excessive Speed Deviation Detection Level
F1-11 Excessive Speed Deviation Detection Delay Time
F1-12 PG 1 Gear Teeth 1
F1-13 PG 1 Gear Teeth 2
F1-14 PG Open-Circuit Detection Time
F1-18 dv3 Detection Selection
F1-19 dv4 Detection Selection
F1-20 PG Option Card Disconnect Detection 1
F1-21 PG 1 Signal Selection
F1-30 PG Option Card Port for Motor 2 Selection
F1-31 PG 2 Pulses Per Revolution
F1-32 PG 2 Rotation Selection
F1-33 PG 2 Gear Teeth 1
F1-34 PG 2 Gear Teeth 2
F1-35 PG 2 Division Rate for PG Pulse Monitor
No. Name
User
Setting
F1-36 PG Option Card Disconnect Detection 2
F1-37 PG2 Signal Selection
F2-01 Analog Input Option Card Operation Selection
F2-02
Analog Input Option Card Gain
F2-03
Analog Input Option Card Bias
F3-01 Digital Input Option Card Input Selection
F3-03 Digital Input Option DI-A3 Data Length Selection
F4-01 Terminal V1 Monitor Selection
F4-02
Terminal V1 Monitor Gain
F4-03 Terminal V2 Monitor Selection
F4-04
Terminal V2 Monitor Gain
F4-05
Terminal V1 Monitor Bias
F4-06
Terminal V2 Monitor Bias
F4-07 Terminal V1 Signal Level
F4-08 Terminal V2 Signal Level
F5-01 Terminal M1-M2 Output Selection
F5-02 Terminal M3-M4 Output Selection
F5-03 Terminal P1-PC Output Selection
F5-04 Terminal P2-PC Output Selection
F5-05 Terminal P3-PC Output Selection
F5-06 Terminal P4-PC Output Selection
F5-07 Terminal P5-PC Output Selection
F5-08 Terminal P6-PC Output Selection
F5-09 DO-A3 Output Mode Selection
F6-01 Communications Error Operation Selection
F6-02
External Fault from Comm. Option Detection
Selection
F6-03
External Fault from Comm. Option Operation
Selection
F6-04 bUS Error Detection Time
F6-06
Torque Reference/Torque Limit Selection from
Comm. Option
F6-07 NetRef/ComRef Function Selection
F6-08 Reset Communication Parameters
F6-10 CC-Link Node Address
F6-11 CC-Link Communications Speed
F6-14 CC-Link bUS Error Auto Reset
F6-20 MECHATROLINK Station Address
F6-21 MECHATROLINK Frame Size
F6-22 MECHATROLINK Link Speed
F6-23 MECHATROLINK Monitor Selection (E)
F6-24 MECHATROLINK Monitor Selection (F)
F6-25 Operation Selection at Watchdog Timer Error (E5)
F6-26 MECHATROLINK bUS Errors Detected
F6-30 PROFIBUS-DP Node Address
E.3 User Setting Table
512
YASKAWA ELECTRIC SIEP C710616 31B YASKAWA AC Drive – A1000 Technical Manual