8 System Setup
8.7 Shock Detection Function
8-81
182582-1CD
182582-1CD
MH900, DX200 Controller
Condition Number (1 to 9)
1 to 7: for changing detection level in play mode.
8: for standard detection level in play mode.
9: for detection level in teach mode.
Robot Select
Select the manipulator whose detection level is to be changed.
Function Select
Specifies VALID/INVALID of the shock detection function. The shock
detection function is specified for each manipulator.
1. Select the manipulator whose function is to be enabled or disabled.
2. Move the cursor to “VALID” or “INVALID” and press [SELECT]. Each
time [SELECT] is pressed, “INVALID” and “VALID” are displayed
alternately. The change is available for all the condition numbers.
Max. Disturbance Force
Indicates the maximum disturbance force to the manipulator when the
manipulator is moved in play back operation or axis operation.
Refer to this value when inputting the detection level value in .
The maximum disturbance force can be cleared by selecting {DATA}
{CLEAR MAX VALUE} in the menu.
Detection Level (Level range: 1 to 500)
Specifies the shock detection level. Set a value larger than the maxi-
mum disturbance force.
The value set by default (the level 100) enables the function without
false detection even if the manipulator is operated at the maximum
speed.
To change DETECT LEVEL, move the cursor to the subject manipula-
tor, and press [SELECT] to display the numeric input status; input the
value with a numeric key and press [ENTER]. To increase the detection
sensitivity, set the level to small value, and to decrease the sensitivity,
set the level to large value.
1
2
3
4
5
1
2
3
4
5
5
168 of 552