8 System Setup
8.7 Shock Detection Function
8-83
182582-1CD
182582-1CD
MH900, DX200 Controller
4. Level setting for the condition number 9.
The level setting for the condition number 9 is for the teach mode.
This setting is made for each group.
Refer to the max. disturbance force to set the DETECT LEVEL.
• Perform all the jobs to use for 5 to 6 hours.
• For handling application, if a work job is performed both
with holding a workpiece and without holding a workpiece,
measure both patterns.
• In the event of a collision while measuring the max.
disturbance force, clear the max. disturbance force by
selecting {DATA}, then {CLEAR MAX VALUE}. Then try
again.
• The max. disturbance force is cleared when the power is
turned ON/OFF. Therefore, DO NOT set the level based
on the max. disturbance force immediately after turning
ON/OFF the power.
• When the teaching point, operation speed, operation
position, etc. of a job are greatly changed due to teaching
modification, etc., measure the max. disturbance force
and set the DETECT LEVEL again.
When the load of tool or workpiece is greatly modified,
measure the max. disturbance force and set the
DETECT LEVEL again.
To avoid false detection during manipulator operation,
set the following calculated value A or B, whichever is
larger, to the DETECT LEVEL. An emergency stop of
the manipulator due to the false detection may become
a factor to damage the speed reducers and tools.
A: (Max. disturbance force) x (coefficient = 120%)
B: (Max. disturbance force) + 15
<Example>
When the max. disturbance force is 80, set the
DETECT LEVEL to 96 or more.
When the max. disturbance force is 10, set the
DETECT LEVEL to 25 or more)