8 System Setup
8.21Preventive Maintenance Function
8-165
182582-1CD
182582-1CD
MH900, DX200 Controller
6. Move the cursor to over the {=REPLACEMENT SIGNAL}, and select.
– Able to enter the values.
7. Enter the universal output signal.
Lifetime Calculation Window
1. Select {=RM} in the main menu.
2. Select {=RM(REDUCER)}.
– The lifetime calculation window appears. In the case of the another
window appears, select {Display}, and select the {=LIFE
CALCULATION} in the pull down menu to display the lifetime
calculation window.
Each item on the screen represents the following description.
=TIME TO REPLACEMENT
Displays the rest of the lifetime to replace the speed reducer. The
calculation of the subtraction of the number is operated automatically by
performing the job in the play mode.
ཱ =NOTICE TIME
By setting the time in this item, the replacement time is informed by
displaying the message and turning the replacement signal ON before the
“TIME TO REPLACEMENT” becomes “0”.
1 2 3 4