EasyManua.ls Logo

YASKAWA DX200 - Page 253

YASKAWA DX200
552 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8-166
182582-1CD
182582-1CD
8 System Setup
8.21Preventive Maintenance Function
MH900, DX200 Controller
For example, when setting with “100”, the message will be displayed 100
hours before the “TIME TO REPLACEMENT” becomes “0”, and the
replacement signal will be turned ON as well.
For example, when setting with “-100”, the message will be displayed 100
hours after the “TIME TO REPLACEMENT” became “0”, and the
replacement signal will be turned ON as well.
=WARNING
Select this item to invalidate the notification signal and displaying the
message. [Invalid] and [Valid] will alternate each time when pressing the
[Select].
=RESET
Select this item after replacing the speed reducer.
Addition to the message is deleted, and the replacement signal is OFF,
“TIME TO REPLACEMENT” is reset.
Invalidate the Replacement Signal and the Message Display
Able to invalidate the replacement signal and the message display in each
axis. Invalidate the replacement signal and the message display by the
following procedures, in the case of the speed reducer seems to operate
normally even though the replacement signal is turned ON.
1. Change the security mode to the management mode.
2. Select {=RM} in the main menu.
3. Select {=RM(REDUCER)}.
The lifetime calculation window appears. In the case of the another
window appears, select {Display}, and select the {=LIFE
CALCULATION} in the pull down menu to display the lifetime
calculation window.
253 of 552