8 System Setup
8.21Preventive Maintenance Function
8-171
182582-1CD
182582-1CD
MH900, DX200 Controller
=CALCULATION DAYS
Set the period to calculate the average value. The initial value of this item
is “30” (days).
=ELAPSED DAYS FROM CALC. START
Set the period to calculate the average value from the day to diagnose.
The initial value of this item is “60” (days).
=LATEST MEASURED DAYS
Set the period to calculate the latest value. The initial value of this item is
“5” (days).
=ERROR DELETE FILTER
Use to delete the error when calculate the average value. The following
values (torque average) are excepted from the calculation of the average
value.
• The average from the previous day exists.
The average from the previous day / any measurement value of the
average period100 ! filter setting value
The any measurement value of the average period / the average
from the previous day100 ! filter setting value
• The average from the previous day does not exist.
The latest value / any measurement value of the average
period100 ! filter setting value
The any measurement value of the average period / the latest
value100 ! filter setting value
The initial value of this item is “200” (%).
=GRAPH NAME
Able to register the name of the graph.
=REPLACEMENT SIGNAL
Use this item to calculate the lifetime. Refer to “Set the Replacement
Notice Signal”.
Even though the initial value is set, the accuracy of the life
diagnosis is not guaranteed performance.