8-172
182582-1CD
182582-1CD
8 System Setup
8.21Preventive Maintenance Function
MH900, DX200 Controller
Data Confirmation
By operating a job in the play mode, a data (the torque element arising
from the deterioration of the speed reducer) for each axis is recorded
automatically on a daily basis, and the data is accumulated. It is
unnecessary to prepare the job for this diagnosis.
Able to refer the data by following procedures.
1. Select {=RM} in the main menu.
2. Select {=RM(REDUCER)}.
3. Select {Display}.
– The pull down menu appears.
4. Select {=TORQUE MONITOR}.
– The torque monitor window appears.
5. Press [PAGE] key.
– Able to refer the data of a date corresponding to the number by
pressing the [PAGE] key. Modify the number as necessary.
Unable to measure the torque average value because the
axis of the measured value indicating “?” is not operating, or
the motion speed is less than the reference speed.
4
5
6
7
8
9
1
2
3