8 System Setup
8.22Break Line Ground Judgment Function
8-197
182582-1CD
182582-1CD
MH900, DX200 Controller
2. Press “YES”.
The confirmation dialog appears due to prevent the mis-operation.
Select “YES”, then the break line ground check appears.
Select “NO”, the window returns to the previous window.
3. Move the cursor over the axis to perform the break line ground check,
and press [SERVO ON READY]. Grip the enable switch and long
press [SELECT] while pressing down the [INTER LOCK] to perform
the break line ground check.
Perform the break line ground check to the every single axis
displayed on the screen.
The break line ground check is canceled in the case of following
conditions.
• [SELECT] is detached.
The emergency button of the programming pendant, controller or
external signal is pressed.
• The servo power is disconnected by the servo power supply
individual control function.
• The servo alarm occurs.
JUDGMENT REQUIRED: The ground check is not performed
BREAKS LINE NORMAL: The break line is normal.