8-206
182582-1CD
182582-1CD
8 System Setup
8.23Safety Logic Circuit
MH900, DX200 Controller
8.23.2.3 Allocating the Safety Signal Board
This window is displayed when the optional safety field bus is valid.
1. Displaying the window.
– Select {SAFETY SIG. BOARD ALLOC} from {SAFETY FUNC.} in
the main menu.
2. Set up the safety field bus signal.
– In the controller, the 64 points of the safety input signal and the 64
points of the safety output signal are present from the safety PLC,
and these signals can be used at the safety logic circuit.
Set the “USE” for the input and output signal(s) to use.
After the setting, the status changes from “DONE” to “NOT DONE”.
The “WRITE” button is displayed on the left down corner of the
screen.