8 System Setup
8.23Safety Logic Circuit
MH900, DX200 Controller
8.23.4.12 Update and Execution of the Safety Logic Circuit
1. Select {SAFETY FUNC.}-{SAFETY LOGIC CIRCUIT}. The safety logic
circuit can be created or edited.
The following is an example to create the safety logic circuit. After the
setting is changed, the status in the title line becomes “NOT DONE” and
“WRITE” menu is displayed.
001 PPDSW SFBOUT01
002 TEACH SFBOUT02
003 SFBIN01 S-SVON_EN
While the safety logic circuit is edited, all the output
signals are OFF.
When updating any of the followings, 1. to 5. are also
update.
1. “SAFETY LOGIC CIRCUIT”
2. “SAFETY LOGIC CIRCUIT EXT. SIGNAL ALLOC”
3. “TIMER DELAY SET”
4. “M-SAFETY SIGNAL ALLOC” (Displayed only when the
safety field bus function is enabled.
5. “F-SAFETY SIGNAL ALLOC” (Displayed only when the
functional safety function is enabled.)
“NOT DONE”
is displayed.
“WRITE” menu
is displayed.