EasyManua.ls Logo

YASKAWA DX200 - Page 371

YASKAWA DX200
552 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8-284
182582-1CD
182582-1CD
8 System Setup
8.24Robot Stop Factor Monitor Function
MH900, DX200 Controller
CONTACTOR OR STO
OFF3
Circuit board No.
SV#1 to SV#8
Servo OFF of the contactor 3 or
STO3 from the main CPU
CONTACTOR OR STO
OFF4
Circuit board No.
SV#1 to SV#8
Servo OFF of the contactor 4 or
STO4 from the main CPU
ON ENABLE1 Circuit board No.
SV#1 to SV#8
Servo OFF of the control group
connected to ON_ENABLE1
ON ENABLE2 Circuit board No.
SV#1 to SV#8
Servo OFF of the control group
connected to ON_ENABLE2
ON ENABLE3 Circuit board No.
SV#1 to SV#8
Servo OFF of the control group
connected to ON_ENABLE3
ON ENABLE4 Circuit board No.
SV#1 to SV#8
Servo OFF of the control group
connected to ON_ENABLE4
CATEGORY ON ENABLE1 Circuit board No.
SV#1 to SV#8
The time of the category 0 is up
after inputting the
ON_ENABLE1 signal, then
switch OFF the servo of the
machine safety.
CATEGORY ON ENABLE2 Circuit board No.
SV#1 to SV#8
The time of the category 0 is up
after inputting the
ON_ENABLE2 signal, then
switch OFF the servo of the
machine safety.
CATEGORY ON ENABLE3 Circuit board No.
SV#1 to SV#8
The time of the category 0 is up
after inputting the
ON_ENABLE3 signal, then
switch OFF the servo of the
machine safety.
CATEGORY ON ENABLE4 Circuit board No.
SV#1 to SV#8
The time of the category 0 is up
after inputting the
ON_ENABLE4 signal, then
switch OFF the servo of the
machine safety.
2ND CONTACTOR1 Circuit board No.
SV#1 to SV#8
2NDSF1
The time of an auxiliary
contactor 1 in the secondary
contactor is up, and switch OFF
the servo of the machine safety.
2ND CONTACTOR2 Circuit board No.
SV#1 to SV#8
2NDSF2
The time of an auxiliary
contactor 2 in the secondary
contactor is up, and switch OFF
the servo of the machine safety.
2ND CONTACTOR3 Circuit board No.
SV#1 to SV#8
2NDSF3
The time of an auxiliary
contactor 3 in the secondary
contactor is up, and switch OFF
the servo of the machine safety.
2ND CONTACTOR4 Circuit board No.
SV#1 to SV#8
2NDSF4
The time of an auxiliary
contactor 4 in the secondary
contactor is up, and switch OFF
the servo of the machine safety.
Table 8-2: The List of the Servo OFF Factors by Machine Safety Circuit Board Instructions
Displayed Item Secondary Indication Description of the Signal
371 of 552

Table of Contents

Other manuals for YASKAWA DX200

Related product manuals