12-39
182582-1CD
182582-1CD
12 Modification of System Configuration
12.3Addition of Base and Station Axes
MH900, DX200 Controller
<Phenomenon1> During motion, the axis moves unsteady on
advance direction.
Confirm the motion with increasing this ratio in each 100.
<Phenomenon2> During pause, the motor makes a lot of noise.
Confirm the motion with decreasing this ratio in each 100.
3. Modify the settings.
If the control axis configuration is changed by addition of a base
axis or station axis, the internal data of the job file are also changed
so that the job file data should be initialized.
Initialize the job file data with procedure “File Initialize” in this
manual after changing the construction.
When the data, motion range for example, should be changed after
the addition of a base axis or station axis, the change can be done
in the same procedure as shown above.
In this case, the control axis configuration is not changed so the job
file data should not be initialized.