5.10 Other Output Signals
5-75
5.10 Other Output Signals
This section explains other output signals.
Use these signals according to the application needs,
e.g., for machine protection.
5.10.1 Servo Alarm Output Signal (ALM) and Alarm Code Output Signals (ALO1,
ALO2, and ALO3)
This section describes signals that are output when the SERVOPACK detects errors and resetting methods.
(1) Servo Alarm Output Signal (ALM)
This signal is output when the SERVOPACK detects an error.
(2) Alarm Code Output Signals (ALO1, ALO2, and ALO3)
The ON/OFF combination of these signals specifies the type of alarm detected by the SERVOPACK.
Use these signals as required to display the contents
of the alarm at the host controller.
For details, refer to 9.1.1 List of Alarms.
Configure an external circuit so that this alarm output turns OFF the main circuit power
supply for the SERVOPACK whenever an error occurs.
Type
Signal
Name
Connector
Pin Number
Setting Meaning
Output ALM CN1-31, 32
ON (closed) Normal SERVOPACK status
OFF (open) SERVOPACK alarm status
Type Signal Name
Connector
Pin Number
Meaning
Output
ALO1 CN1-37 Alarm code output
ALO2 CN1-38 Alarm code output
ALO3 CN1-39 Alarm code output
SG CN1-1 Signal ground for alarm code output