5.4 Position Control
5-41
5
Operation
5.4.2 Clear Signal Setting
Clear input signal sets SERVOPACK error counter to zero.
(1) Connecting the Clear Signal
(2) Clear Input Signal Form
Set the clear input signal form using Pn200.1.
The following items will be changed in the SERVOPACK after the error
counter has been reset to zero.
The SERVOPACK error counter is set to 0.
The position loop operation is disabled.
Note: Holding the clear status may cause the servolock to stop functioning and the servomotor to move slowly due to drift
in the speed loop.
Pulse Width of Clear Signal
When parameter Pn200.1 is set to 0 or 2, the width of the clear signal must be at least 250 s to reset the error
counter.
When parameter Pn200.1 is set to 1 or 3, the width
of the clear signal must be at least 20 s to reset the error
counter.
(3) Clear Operation
This parameter determines when the position error should be set to zero according to the condition of the SER-
VOPACK. Any of three clearing modes
can be selected with Pn200.2.
Type Signal Name Connector Pin Number Name
Input
CLR CN1-15
Clear input
/CLR CN1-14
Parameter Description Clear Timing
When
Enabled
Classification
Pn200
n.0
[Fac
tory setting]
Clears at ON.
Position errors do not
accumulate while the sig-
nal is ON.
After restart Setup
n.1 Clears at the rising edge.
n.2
Clears at OFF.
Position errors do not
accumulate while the sig-
nal is OFF.
n.3 Clears at the falling edge.
Clears at
ON.
CLR
(CN1-15)
ON
Clears here just once.
CLR
(CN1-15)
OFF.
CLR
(CN1-15)
Clears at
OFF
Clears here just once.
CLR
(CN1-15)
Parameter Description
When
Enabled
Classification
Pn200
n.0
[Factory setting]
Sets the position error to zero durin
g a baseblock when
an alarm occurs or when the servo ON signal (/S-ON)
turns OFF.
After restart Setup
n.1
Does not set the error counter to zero.
Clears the posi-
tion error only with the CLR signal.
n.2 Sets the position error to zero when an alarm occurs.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA SGDV SERVOPACK and is the answer not in the manual?

YASKAWA SGDV SERVOPACK Specifications

General IconGeneral
ModelSGDV
TypeSERVOPACK
Control ModesPosition, Speed, Torque
Communication InterfaceMECHATROLINK-II, MECHATROLINK-III, EtherCAT
Protection RatingIP20
Operating Temperature0°C to 55°C
Vibration Resistance5.9 m/s² (0.6G) at 10-60Hz
Shock Resistance49 m/s² (5G)
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overload, Regenerative overload, Encoder error