7.10 Automatic Offset-Signal Adjustment of the Motor Current Detection Signal (Fn00E)
7-17
7
Utility Functions (Fn)
7.10 Automatic Offset-Signal Adjustment of the Motor Current
Detection Signal (Fn00E)
Perform this adjustment only if highly accurate adjustment is required for reducing force ripple caused by cur-
rent offset. The user need not usually use this function.
Note: The adjusted value is not initialized by executing the Fn005 function (Initializing Parameter Settings).
(1) Preparation
The following conditions must be met to automatically adjust the offset of the motor current detection signal.
The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
The SERVOPACK must be in Servo Ready status (Refer to 5.10.4).
The servo ON signal (/S-ON) must be OFF.
(2) Operating Procedure
Use the following procedure.
• Be sure to perform this function while the servo ON signal (/S-ON) is OFF.
• Execute the automatic offset adjustment if
the force ripple is too big when compared
with those of other SERVOPACKs.
Step
Display after Opera-
tion
Keys Operation
1 Press the MODE/SET Key to select the utility function.
2 Press the UP or DOWN Key to select Fn00E.
3
Press the DATA/SHIFT Key for approximately one second.
The screen shown on the left will be displayed.
4
Press the MODE/SET Key to perform automatic offset
adjustment. After
the adjustment is completed, "donE"
flashes on the display and the screen returns to the message
shown on the left.
5
Press the DATA/SHIFT Key for approximately one second.
"Fn00E" is
displayed again.
MODE
/
SET
DATA
/
MODE
/
SET
DATA
/
MODE
/
SET
DATA
/
MODE
/
SET
DATA
/
MODE
/
SET
DATA
/

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA SGDV SERVOPACK and is the answer not in the manual?

YASKAWA SGDV SERVOPACK Specifications

General IconGeneral
ModelSGDV
TypeSERVOPACK
Control ModesPosition, Speed, Torque
Communication InterfaceMECHATROLINK-II, MECHATROLINK-III, EtherCAT
Protection RatingIP20
Operating Temperature0°C to 55°C
Vibration Resistance5.9 m/s² (0.6G) at 10-60Hz
Shock Resistance49 m/s² (5G)
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overload, Regenerative overload, Encoder error