6.2 Tuning-less Function
6-17
6
Adjustments
6.2.3 Related Parameters
The following table lists parameters related to this function and their possibility of being changed while exe-
cuting this function or of being changed automatically after executing this function.
Parameters related to this function
These are parameters that are used or referenced when
executing this function.
Allowed changes during execution of this function
Yes : Parameters can be changed using SigmaWin+ while this function is being executed.
No
: Parameters cannot be changed using SigmaWin+ while this function is being executed.
Automatic changes after execution of this function
Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.
Parameter Name
Mid-execution
changes
Automatic
changes
Pn170 Tuning-less Function Related Switch No Yes
Pn401 Force Reference Filter Time Constant No Yes
Pn40C 2nd Notch Filter Frequency No Yes
Pn40D 2nd Notch Filter Q Value No Yes

Table of Contents