Section 4, EoCu Provisioning - Provision the 32-Port SHDSL EFM
65K510DEP08-1A 4-5
Ifconnectedto the shelfwherethemoduleresides,theshelfnumberis
typically1.
2. FromtheGlobalConfigurationprompt,provisionthemoduleadministrationstateby
performingoneofthefollowingcommands:
•Type
no slot shutdown <shelf/slot>,andpressENTERtotaketheslotInService
•Type
slot shutdown maintenance <shelf/slot>,andpressENTERtotakethe
slotOutofServiceMaintenance
•Type
slot shutdown <shelf/slot>,andpressENTERtotaketheslotOutof
Service,Unassigned
3. FromtheGlobalConfigurationprompt,type
interface shdsl <shelf/slot/port>,
andpress
ENTER.
4. ToconfiguretheCircuitID,type
description LINE,andpressENTER.
5. ProvisiontheSHDSLportadministrationstatebyperformingoneofthefollowing
commands:
•Type
no shutdown,andpressENTERtotaketheportInService
•Type
shutdown maintenance,andpressENTERtotaketheportOutofService,
Maintenance
•Type
shutdown,andpressENTERtotaketheportOutofService,Unassigned
6. Tosetthealarmthresholds,type
thresholds [cvc|es|losws|ses|uas] [15
minute|24 hour] <0-2147483647>
,andpressENTER.
Table4‐3providesthesyntaxandalarmthresholddefinitionsforarg_1andarg_2.
7. Repeatsteps3‐8foreachSHDSLportthatneedstobeprovisioned.
8. Type
end,andpressENTERtoreturntotheEnableprompt.
Table 4-3. 32-Port SHDSL EFM Alarm Thresholds
Syntax Definition
arg_1 Selectthethresholdtoconfigurethefollowing:
•cvc‐CodeViolationCount
•es‐ErroredSeconds
•losws‐LossofSyncWordSeconds
•ses‐SeverelyErroredSeconds
•uas‐UnavailableSeconds
arg_2 Enterthesecondalarmthresholdtooneofthefollowing:
•15‐minute‐Thisreportsanyviolationswithina15‐minutetime
frame.Validvaluesare0‐2147483647.
•24‐hour‐Thisreportsanyviolationswithina24‐hourtimeframe.
Validvaluesare0‐2147483647.