Total Access 5000 Business Services Deployment Guide
4-22 65K510DEP08-1A
Provisioning Steps
TocreateanEVC,completethefollowingprocedure:
1. FromtheEnableprompt,type
configure terminal,andpressENTERtoaccesstheGlo‐
balConfigurationprompt.
2. FromtheGlobalConfigurationprompt,type
evc WORD,andpressENTER tocreatean
EVC.
TheWORDattributeisanarbitrarystringthatisusedtoidentifytheEVCwithinthe
MEN.ThevaluemustbeuniqueacrossallEVCsdefinedintheNetVanta838,andis
intendedformanagementandcontrolpurposes.Thevalueisnotcarriedinanyfieldin
theEthernetframe.
ThiscreatestheEVCandenablestheEVCConfigurationprompt.
Configure the EVC
TheMENportandS‐tagmustbeconfiguredfortheEVC.ToconfiguretheMetroEthernet
NetworkandS‐tag,completethefollowingprocedure:
1. FromtheEVCConfigurationprompt,type
connectmen-port efm-group 1/0/1,and
press
ENTER tosettheMEN‐portasanEFMbondinggroupoftheNetVanta838.
ThisattributeisthelogicalinterfaceconnectedtotheMEN.Thepossibleoptionsconsist
oftheEthernetport(s)andbondinggroup(s )availableontheNetVanta838.Intypical
configurations,theMENportisspecifiedasabonding
group.
2. FromtheEVCConfigurationprompt,settheS‐tagbytyping
s-tag <2-4094>,and
press
ENTER.
ThisattributeistheVLANIDassociatedwiththeEVCtag.
TheNetVanta838S‐tagmustmatchtheS‐tagprovisionedintheTotalAccess
5000forthisbondinggrou p.IftheS‐tagisnotconfiguredattheTotalAccess
5000,theEVCwillnotgorunning.
3. Bydefault,CEVLANPreservationisenabled.Todisable,type
no preserve-ce-vlan,
andpress
ENTER.
IfCEVLANPreservationisenabled,theNetVantapreservesthecustomer’sVLANtag
fortrafficenteringtheNetVanta.Itstackstheserviceprovidertagontopofthecustomer
tag.Ifitisdisabled,thecustomerVLANtagisstrippedbeforetheserviceprovidertagis
addedtothetraffic.
IfCEVLANPreservationisdisabled,thecustomertagisaddedbackontotraffic
egressingtothecustomer.
4. Bydefault,thenewEVCisdisabled.EnablethenewEVCbytyping
no shutdown,and
press
ENTER.
5. Type
exitandpressENTERtoreturntotheGlobalConfigurationprompt.
6. Type
exitandpressENTERtoreturntotheEnableprompt.
7. Tosavethechangesinnon‐volatilememory,type
write,andpressENTER.
8. ViewthenewEVCbytypingshow evc WORD,andpressENTER.