Total Access 5000 Business Services Deployment Guide
6-10 65K510DEP08-1A
OncecompletedandifthemanagementVLANsoftheGigESMandtheNetVanta800are
equivalent,theNetVanta800CommandLineInterface(CLI)canbeaccessedviatheInband
ManagementVLAN.
Modify an Existing Bridge
TherearetwowaystomodifyanexistingEFMbondinggroup.TheEZEFMapplication
allowstheusertoaddorremovealinkto/fromabondinggroupwhilesimultaneouslyspeci
fyingthebondinggroupupstreamanddownstreamdatarates.TheEZEFMapplication
automaticallyreprovisionsalllinksinthe
grouptothenecessarylinkrates,whethertherate
isincreasedordecreased.Thelinksretainandprovidetheprovisioneddatarate.
Thesecondwaytoaddorremovealinkto/fromagroupisbydirectlymodifyingtheEFM
bondinggroupintheEFMBondingGroupConfigurationprompt.Thismethod
doesnot
resultinareprovisioningofthelinksinthegroup, butcanresultinthelinksnotbeingsetto
theoptimumrates,oreveninthegroupnotprovidingthespecifieddatarateiflinksare
removed.
Modify a Bonding Group with EZ-EFM
TomodifyabondinggroupusingtheEZEFMapplication,completethefollowing:
1. FromtheEnableprompt,type
application,andpressENTERtoaccesstheApplication
Configurationprompt.
2. FromtheApplication Configurationprompt,type
ez-efm 1and pressENTERtostartthe
EZEthernetapplication.
3. FromtheEFMConfigurationprompt,typeoneofthefollowingcommandstomodifyan
existingEFMBondingGroup:
•ToprovisiontheDS3EFM4Port,type
modify <group_name> link <slot/
port> upstream <0-250000> downstream <0-250000> active-links-
minimum <1-n>
, andpressENTER.
•ToprovisiontheDS3EFM3Port,type
modify <group_name> link <slot/
port:channel> upstream <0-250000> downstream <0-250000> active-
links-minimum <1-n>
, andpressENTER.
RefertoTable 63 onpage 67forthelistofvariablesfortheEFMbondinggroup.
4. FromtheEFMConf igurationprompt,typeoneofthefollowingcommandstoremove
linksfromanexistingEFMBondingGroup:
•ToprovisiontheDS3EFM4Port,type
modify <group_name> no-link <slot/
port> upstream <0-250000> downstream <0-250000> active-links-
minimum <1-n>
, andpressENTER.
•ToprovisiontheDS3EFM3Port,type
modify <group_name> no-link <slot/
port:channel> upstream <0-250000> downstream <0-250000> active-
links-minimum <1-n>
, andpressENTER.
NOTE
Forthe modifycommand,allparameters mustbe specified, evenifa
particularvalueisnotbeingchanged.